United States of America · Generator · plant location

Chief Joseph / 11

공식 원천의 전력 객체 · Out of service

Project stage · source basis
Stage requires verification · out_of_service
Reported operator
USACE Northwestern Division
Address
Check each original source
Data Reference Date
2026-08
Collection review date
2026-10-05
Location meaning
Plant location · not an individual generator location · Accuracy not disclosed
Coordinates and geometry
47.9951, -119.6404

These are source records. Operator labels do not confirm legal ownership or operations. Map locations do not verify supplying substations, power contracts or current available capacity.

Power assets and projects · USA · eia860m

Chief Joseph / 11

Generator · Out of service

Metric or conditionSource valueBasis, scope and stage
Nameplate Capacity (MW)88.2 MWOriginal source column definition · Generator · (OA) Out of service but expected to return to service in next calendar year
As-of date 2026-08
Sources EV-b7c79e695078a660bbf84538
Net Summer Capacity (MW)88.2 MWOriginal source column definition · Generator · (OA) Out of service but expected to return to service in next calendar year
As-of date 2026-08
Sources EV-b7c79e695078a660bbf84538
Net Winter Capacity (MW)88.2 MWOriginal source column definition · Generator · (OA) Out of service but expected to return to service in next calendar year
As-of date 2026-08
Sources EV-b7c79e695078a660bbf84538
Detailed source fields
Original source fieldPublished value or condition
Entity ID19400
Entity NameUSACE Northwestern Division
Plant ID3921
Plant NameChief Joseph
Google MapMap
Bing MapMap
Plant StateWA
CountyDouglas
Balancing Authority CodeBPAT
SectorElectric Utility
Generator ID11
Nameplate Capacity (MW)88.2
Net Summer Capacity (MW)88.2
Net Winter Capacity (MW)88.2
TechnologyConventional Hydroelectric
Energy Source CodeWAT
Prime Mover CodeHY
Operating Month9
Operating Year1955
Status(OA) Out of service but expected to return to service in next calendar year
Latitude47.9951
Longitude-119.6404
Original text(OA) Out of service but expected to return to service in next calendar year
Coordinate accuracysource_precision_not_independently_surveyed
source_record_idOperating:5451

Parent facility or plant record

Coordinates locate the plant, including when this record describes one generator.

Location: Plant location · not an individual generator location

Sources, reference dates and retrieval dates 2items
eia860 ↗

Data Source 2025 · Retrieved 2026-10-05

Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.

Source location 3_1_Generator_Y2025.xlsx#Operable:5446

Sources EV-748ee67a927e5db200ba3e35
Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba
행 SHA-256 34e64755c21b73efd9c4a1c07cdff5539cd2e8aaffbea9eafd734caa924e096e

Usage terms US government public domain

eia860m ↗

Data Source 2026-08 · Retrieved 2026-10-05

Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.

Source location Operating:5451

Sources EV-b7c79e695078a660bbf84538
Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c
행 SHA-256 df3dc1f0189de3779e6bfa9662c970e07bdd93d4e541dcbeb1563c25f2793636

Usage terms US government public domain

Related power and facility evidence

Loading related evidence…

Other records with the same country and operator label

These source records have not been merged as a confirmed legal entity or campus.

Find related records →

AI-DC KOREA MEMBER

Log In

Sign in to continue on this page.

G Continue with GoogleK Continue with Kakao

Choose the Google or Kakao account you registered with.

Start a consultation · Choose a channel