POWER & FACILITY EVIDENCE

Power and Facility Evidence Database

Review power assets, contract observations, facility specifications and relationships from public sources.

This partial collection preserves source-level observations. Generation and registered connection capacity are distinct from spare supply capacity for data centers. Planned dates and contract announcements do not confirm energization or supply commencement.

Current filters 3items · current page 1–3 · Source records, not unique facilities.

Power assets and projects · USA · eia860m

Caledonia / STG1

Generator · Operations

Metric or conditionSource valueBasis, scope and stage
Nameplate Capacity (MW)106 MWOriginal source column definition · Generator · (OP) Operating
As-of date 2026-08
Sources EV-e5623199301b953d811e80a2
Net Summer Capacity (MW)98 MWOriginal source column definition · Generator · (OP) Operating
As-of date 2026-08
Sources EV-e5623199301b953d811e80a2
Net Winter Capacity (MW)105 MWOriginal source column definition · Generator · (OP) Operating
As-of date 2026-08
Sources EV-e5623199301b953d811e80a2
Detailed source fields
Original source fieldPublished value or condition
Entity ID18642
Entity NameTennessee Valley Authority
Plant ID55197
Plant NameCaledonia
Google MapMap
Bing MapMap
Plant StateMS
CountyLowndes
Balancing Authority CodeTVA
SectorElectric Utility
Generator IDSTG1
Unit CodeCCC1
Nameplate Capacity (MW)106
Net Summer Capacity (MW)98
Net Winter Capacity (MW)105
TechnologyNatural Gas Fired Combined Cycle
Energy Source CodeNG
Prime Mover CodeCA
Operating Month6
Operating Year2003
Status(OP) Operating
Latitude33.6464
Longitude-88.2717
Original text(OP) Operating
Coordinate accuracysource_precision_not_independently_surveyed
source_record_idOperating:11565

Parent facility or plant record

Coordinates locate the plant, including when this record describes one generator.

Location: Plant location · not an individual generator location

Sources, reference dates and retrieval dates 2items
eia860 ↗

Data Source 2025 · Retrieved 2026-10-05

Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.

Source location 3_1_Generator_Y2025.xlsx#Operable:11565

Sources EV-dc911e01b1f27480ae41c94b
Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba
행 SHA-256 8c4099f9f201dbef917f5fe09d3c676b4f4c41be0b627b7637fca26179c5484c

Usage terms US government public domain

eia860m ↗

Data Source 2026-08 · Retrieved 2026-10-05

Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.

Source location Operating:11565

Sources EV-e5623199301b953d811e80a2
Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c
행 SHA-256 9572cfa8b3debb9b0dc2db54196974423fbb0bb22981282a33a5728d696ae18e

Usage terms US government public domain

Source snapshots by date · USA · eia860m

Caledonia / STG1

Generator · Operations

Metric or conditionSource valueBasis, scope and stage
Detailed source fields
Original source fieldPublished value or condition
Entity ID18642
Entity NameTennessee Valley Authority
Plant ID55197
Plant NameCaledonia
Google MapMap
Bing MapMap
Plant StateMS
CountyLowndes
Balancing Authority CodeTVA
SectorElectric Utility
Generator IDSTG1
Unit CodeCCC1
Nameplate Capacity (MW)106
Net Summer Capacity (MW)98
Net Winter Capacity (MW)105
TechnologyNatural Gas Fired Combined Cycle
Energy Source CodeNG
Prime Mover CodeCA
Operating Month6
Operating Year2003
Status(OP) Operating
Latitude33.6464
Longitude-88.2717
Original text(OP) Operating
source_record_idOperating:11565

Parent facility or plant record

No separate metric summary is available. Consult the detailed source fields.

Sources, reference dates and retrieval dates 1items
eia860m ↗

Data Source 2026-08 · Retrieved 2026-10-05

Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.

Source location Operating:11565

Sources EV-e5623199301b953d811e80a2
Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c
행 SHA-256 9572cfa8b3debb9b0dc2db54196974423fbb0bb22981282a33a5728d696ae18e

Usage terms US government public domain

Source snapshots by date · USA · eia860

Caledonia / STG1

Generator · Operations

Metric or conditionSource valueBasis, scope and stage
Detailed source fields
Original source fieldPublished value or condition
Utility ID18642
Utility NameTennessee Valley Authority
Plant Code55197
Plant NameCaledonia
StateMS
CountyLowndes
Generator IDSTG1
TechnologyNatural Gas Fired Combined Cycle
Prime MoverCA
Unit CodeCCC1
OwnershipW
Duct BurnersY
Can Bypass Heat Recovery Steam Generator?X
Nameplate Capacity (MW)106
Nameplate Power Factor0.9
Summer Capacity (MW)98
Winter Capacity (MW)105
Minimum Load (MW)73.7
Uprate or Derate Completed During YearN
StatusOP
Synchronized to Transmission GridX
Operating Month6
Operating Year2003
Associated with Combined Heat and Power SystemN
Sector NameElectric Utility
Sector1
Topping or BottomingX
Energy Source 1NG
Solid Fuel Gasification System?N
Carbon Capture Technology?N
Time from Cold Shutdown to Full Load12H
Multiple Fuels?N
Original textOP
source_record_id3_1_Generator_Y2025.xlsx#Operable:11565

Parent facility or plant record

No separate metric summary is available. Consult the detailed source fields.

Sources, reference dates and retrieval dates 1items
eia860 ↗

Data Source 2025 · Retrieved 2026-10-05

Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.

Source location 3_1_Generator_Y2025.xlsx#Operable:11565

Sources EV-dc911e01b1f27480ae41c94b
Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba
행 SHA-256 8c4099f9f201dbef917f5fe09d3c676b4f4c41be0b627b7637fca26179c5484c

Usage terms US government public domain

AI-DC KOREA MEMBER

Log In

Sign in to continue on this page.

G Continue with GoogleK Continue with Kakao

Choose the Google or Kakao account you registered with.

Start a consultation · Choose a channel