POWER & FACILITY EVIDENCE
Power and Facility Evidence Database Review power assets, contract observations, facility specifications and relationships from public sources.
Global Facilities and Power Map Korea Site and Power Map Korea Data Center Database This partial collection preserves source-level observations. Generation and registered connection capacity are distinct from spare supply capacity for data centers. Planned dates and contract announcements do not confirm energization or supply commencement.
Current filters 3items · current page 1–3 · Source records, not unique facilities.
Power assets and projects · USA · eia860m Gallatin (TN) / 3 Generator · Operations
Metric or condition Source value Basis, scope and stage Nameplate Capacity (MW) 327.6 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-06924aecfd339349d446d8cc Net Summer Capacity (MW) 263 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-06924aecfd339349d446d8cc Net Winter Capacity (MW) 266 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-06924aecfd339349d446d8cc
Detailed source fields Original source field Published value or condition Entity ID 18642 Entity Name Tennessee Valley Authority Plant ID 3403 Plant Name Gallatin (TN) Google Map Map Bing Map Map Plant State TN County Sumner Balancing Authority Code TVA Sector Electric Utility Generator ID 3 Nameplate Capacity (MW) 327.6 Net Summer Capacity (MW) 263 Net Winter Capacity (MW) 266 Technology Conventional Steam Coal Energy Source Code SUB Prime Mover Code ST Operating Month 5 Operating Year 1959 Planned Retirement Month 12 Planned Retirement Year 2031 Status (OP) Operating Latitude 36.3156 Longitude -86.4006 Original text (OP) Operating Coordinate accuracy source_precision_not_independently_surveyed source_record_id Operating:4840
Parent facility or plant record
Coordinates locate the plant, including when this record describes one generator.
Location: Plant location · not an individual generator location
Sources, reference dates and retrieval dates 2items eia860 ↗ Data Source 2025 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location 3_1_Generator_Y2025.xlsx#Operable:4835
Sources EV-58bacb4e742285d131b56944 Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba 행 SHA-256 9e07b506bd881abb2aef4cc097eb4dd07848b364d0dc09b6865720baf2e83614 Usage terms US government public domain
eia860m ↗ Data Source 2026-08 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location Operating:4840
Sources EV-06924aecfd339349d446d8cc Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c 행 SHA-256 688773130adbe0581f3d320bf6887a3a196f27c7b02cb798815eea7eb53075da Usage terms US government public domain
Observations for this power asset View on the global map Source snapshots by date · USA · eia860 Gallatin (TN) / 3 Generator · Operations
Metric or condition Source value Basis, scope and stage
Detailed source fields Original source field Published value or condition Utility ID 18642 Utility Name Tennessee Valley Authority Plant Code 3403 Plant Name Gallatin (TN) State TN County Sumner Generator ID 3 Technology Conventional Steam Coal Prime Mover ST Ownership S Duct Burners X Can Bypass Heat Recovery Steam Generator? X Nameplate Capacity (MW) 327.6 Nameplate Power Factor 0.9 Summer Capacity (MW) 263 Winter Capacity (MW) 266 Minimum Load (MW) 130 Uprate or Derate Completed During Year N Status OP Synchronized to Transmission Grid X Operating Month 5 Operating Year 1959 Planned Retirement Month 12 Planned Retirement Year 2031 Associated with Combined Heat and Power System N Sector Name Electric Utility Sector 1 Topping or Bottoming X Energy Source 1 SUB Energy Source 2 BIT Startup Source 1 DFO Solid Fuel Gasification System? N Carbon Capture Technology? N Time from Cold Shutdown to Full Load OVER Pulverized Coal Technology? Y Subcritical Technology? Y Multiple Fuels? Y Original text OP source_record_id 3_1_Generator_Y2025.xlsx#Operable:4835
Parent facility or plant record
No separate metric summary is available. Consult the detailed source fields.
Sources, reference dates and retrieval dates 1items eia860 ↗ Data Source 2025 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location 3_1_Generator_Y2025.xlsx#Operable:4835
Sources EV-58bacb4e742285d131b56944 Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba 행 SHA-256 9e07b506bd881abb2aef4cc097eb4dd07848b364d0dc09b6865720baf2e83614 Usage terms US government public domain
Observations for this power asset Source snapshots by date · USA · eia860m Gallatin (TN) / 3 Generator · Operations
Metric or condition Source value Basis, scope and stage
Detailed source fields Original source field Published value or condition Entity ID 18642 Entity Name Tennessee Valley Authority Plant ID 3403 Plant Name Gallatin (TN) Google Map Map Bing Map Map Plant State TN County Sumner Balancing Authority Code TVA Sector Electric Utility Generator ID 3 Nameplate Capacity (MW) 327.6 Net Summer Capacity (MW) 263 Net Winter Capacity (MW) 266 Technology Conventional Steam Coal Energy Source Code SUB Prime Mover Code ST Operating Month 5 Operating Year 1959 Planned Retirement Month 12 Planned Retirement Year 2031 Status (OP) Operating Latitude 36.3156 Longitude -86.4006 Original text (OP) Operating source_record_id Operating:4840
Parent facility or plant record
No separate metric summary is available. Consult the detailed source fields.
Sources, reference dates and retrieval dates 1items eia860m ↗ Data Source 2026-08 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location Operating:4840
Sources EV-06924aecfd339349d446d8cc Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c 행 SHA-256 688773130adbe0581f3d320bf6887a3a196f27c7b02cb798815eea7eb53075da Usage terms US government public domain
Observations for this power asset