POWER & FACILITY EVIDENCE
Power and Facility Evidence Database Review power assets, contract observations, facility specifications and relationships from public sources.
Global Facilities and Power Map Korea Site and Power Map Korea Data Center Database This partial collection preserves source-level observations. Generation and registered connection capacity are distinct from spare supply capacity for data centers. Planned dates and contract announcements do not confirm energization or supply commencement.
Current filters 3items · current page 1–3 · Source records, not unique facilities.
Power assets and projects · USA · eia860m Parr GT / GT5 Generator · Operations
Metric or condition Source value Basis, scope and stage Nameplate Capacity (MW) 65.4 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-817ed78ebfd6d973130d51e0 Net Summer Capacity (MW) 42 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-817ed78ebfd6d973130d51e0 Net Winter Capacity (MW) 52 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-817ed78ebfd6d973130d51e0
Detailed source fields Original source field Published value or condition Entity ID 17539 Entity Name Dominion Energy South Carolina, Inc Plant ID 3291 Plant Name Parr GT Google Map Map Bing Map Map Plant State SC County Fairfield Balancing Authority Code SCEG Sector Electric Utility Generator ID GT5 Nameplate Capacity (MW) 65.4 Net Summer Capacity (MW) 42 Net Winter Capacity (MW) 52 Technology Natural Gas Fired Combustion Turbine Energy Source Code NG Prime Mover Code GT Operating Month 12 Operating Year 2025 Status (OP) Operating Latitude 34.2642 Longitude -81.3308 Original text (OP) Operating Coordinate accuracy source_precision_not_independently_surveyed source_record_id Operating:4728
Parent facility or plant record
Coordinates locate the plant, including when this record describes one generator.
Location: Plant location · not an individual generator location
Sources, reference dates and retrieval dates 2items eia860 ↗ Data Source 2025 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location 3_1_Generator_Y2025.xlsx#Operable:4723
Sources EV-fa894705ecce08864cac90e3 Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba 행 SHA-256 7a17951336d3076ec1f991d8f41480ad0cf840b93093c74e1b4890549aaf476b Usage terms US government public domain
eia860m ↗ Data Source 2026-08 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location Operating:4728
Sources EV-817ed78ebfd6d973130d51e0 Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c 행 SHA-256 018e500d28223dcf3cbd07963a20e2e52a72047b38de37658406ceb32eedef19 Usage terms US government public domain
Observations for this power asset View on the global map Source snapshots by date · USA · eia860m Parr GT / GT5 Generator · Operations
Metric or condition Source value Basis, scope and stage
Detailed source fields Original source field Published value or condition Entity ID 17539 Entity Name Dominion Energy South Carolina, Inc Plant ID 3291 Plant Name Parr GT Google Map Map Bing Map Map Plant State SC County Fairfield Balancing Authority Code SCEG Sector Electric Utility Generator ID GT5 Nameplate Capacity (MW) 65.4 Net Summer Capacity (MW) 42 Net Winter Capacity (MW) 52 Technology Natural Gas Fired Combustion Turbine Energy Source Code NG Prime Mover Code GT Operating Month 12 Operating Year 2025 Status (OP) Operating Latitude 34.2642 Longitude -81.3308 Original text (OP) Operating source_record_id Operating:4728
Parent facility or plant record
No separate metric summary is available. Consult the detailed source fields.
Sources, reference dates and retrieval dates 1items eia860m ↗ Data Source 2026-08 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location Operating:4728
Sources EV-817ed78ebfd6d973130d51e0 Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c 행 SHA-256 018e500d28223dcf3cbd07963a20e2e52a72047b38de37658406ceb32eedef19 Usage terms US government public domain
Observations for this power asset Source snapshots by date · USA · eia860 Parr GT / GT5 Generator · Operations
Metric or condition Source value Basis, scope and stage
Detailed source fields Original source field Published value or condition Utility ID 17539 Utility Name Dominion Energy South Carolina, Inc Plant Code 3291 Plant Name Parr GT State SC County Fairfield Generator ID GT5 Technology Natural Gas Fired Combustion Turbine Prime Mover GT Ownership S Duct Burners X Can Bypass Heat Recovery Steam Generator? X Nameplate Capacity (MW) 65.4 Nameplate Power Factor 0.85 Summer Capacity (MW) 42 Winter Capacity (MW) 52 Minimum Load (MW) 18 Uprate or Derate Completed During Year N Status OP Synchronized to Transmission Grid X Operating Month 12 Operating Year 2025 Sector Name Electric Utility Sector 1 Energy Source 1 NG Solid Fuel Gasification System? N Carbon Capture Technology? N Time from Cold Shutdown to Full Load 10M Multiple Fuels? N Cofire Fuels? N Switch Between Oil and Natural Gas? N Original text OP source_record_id 3_1_Generator_Y2025.xlsx#Operable:4723
Parent facility or plant record
No separate metric summary is available. Consult the detailed source fields.
Sources, reference dates and retrieval dates 1items eia860 ↗ Data Source 2025 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location 3_1_Generator_Y2025.xlsx#Operable:4723
Sources EV-fa894705ecce08864cac90e3 Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba 행 SHA-256 7a17951336d3076ec1f991d8f41480ad0cf840b93093c74e1b4890549aaf476b Usage terms US government public domain
Observations for this power asset