POWER & FACILITY EVIDENCE
Power and Facility Evidence Database Review power assets, contract observations, facility specifications and relationships from public sources.
Global Facilities and Power Map Korea Site and Power Map Korea Data Center Database This partial collection preserves source-level observations. Generation and registered connection capacity are distinct from spare supply capacity for data centers. Planned dates and contract announcements do not confirm energization or supply commencement.
Current filters 3items · current page 1–3 · Source records, not unique facilities.
Power assets and projects · USA · eia860m Belden / 1 Generator · Operations
Metric or condition Source value Basis, scope and stage Nameplate Capacity (MW) 117.9 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-b570d42ad715fe56b93a8b5c Net Summer Capacity (MW) 125 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-b570d42ad715fe56b93a8b5c Net Winter Capacity (MW) 125 MW Original source column definition · Generator · (OP) Operating As-of date 2026-08 Sources EV-b570d42ad715fe56b93a8b5c
Detailed source fields Original source field Published value or condition Entity ID 14328 Entity Name Pacific Gas & Electric Co. Plant ID 219 Plant Name Belden Google Map Map Bing Map Map Plant State CA County Plumas Balancing Authority Code CISO Sector Electric Utility Generator ID 1 Nameplate Capacity (MW) 117.9 Net Summer Capacity (MW) 125 Net Winter Capacity (MW) 125 Technology Conventional Hydroelectric Energy Source Code WAT Prime Mover Code HY Operating Month 9 Operating Year 1969 Status (OP) Operating Latitude 40.007445 Longitude -121.2494 Original text (OP) Operating Coordinate accuracy source_precision_not_independently_surveyed source_record_id Operating:414
Parent facility or plant record
Coordinates locate the plant, including when this record describes one generator.
Location: Plant location · not an individual generator location
Sources, reference dates and retrieval dates 2items eia860 ↗ Data Source 2025 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location 3_1_Generator_Y2025.xlsx#Operable:412
Sources EV-c170a24418642d0fc6fab76f Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba 행 SHA-256 5d459c3ec2e81d869a264ad8c1e39da5a37cfa82b8f6b94741b9a6e92a81468d Usage terms US government public domain
eia860m ↗ Data Source 2026-08 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location Operating:414
Sources EV-b570d42ad715fe56b93a8b5c Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c 행 SHA-256 e1d7d2a0ec9bcb8de0f6c100ea0fec26cf6c86fe4946152104b27e5961ea218d Usage terms US government public domain
Observations for this power asset View on the global map Source snapshots by date · USA · eia860 Belden / 1 Generator · Operations
Metric or condition Source value Basis, scope and stage
Detailed source fields Original source field Published value or condition Utility ID 14328 Utility Name Pacific Gas & Electric Co. Plant Code 219 Plant Name Belden State CA County Plumas Generator ID 1 Technology Conventional Hydroelectric Prime Mover HY Ownership S Duct Burners X Can Bypass Heat Recovery Steam Generator? X RTO/ISO LMP Node Designation BELDEN_7_B1 RTO/ISO Location Designation for Reporting Wholesale Sales Data to FERC BELDEN_7_B1 Nameplate Capacity (MW) 117.9 Nameplate Power Factor 0.9 Summer Capacity (MW) 125 Winter Capacity (MW) 125 Minimum Load (MW) 0 Uprate or Derate Completed During Year N Status OP Synchronized to Transmission Grid X Operating Month 9 Operating Year 1969 Associated with Combined Heat and Power System N Sector Name Electric Utility Sector 1 Topping or Bottoming X Energy Source 1 WAT Solid Fuel Gasification System? N Time from Cold Shutdown to Full Load 10M Multiple Fuels? N Original text OP source_record_id 3_1_Generator_Y2025.xlsx#Operable:412
Parent facility or plant record
No separate metric summary is available. Consult the detailed source fields.
Sources, reference dates and retrieval dates 1items eia860 ↗ Data Source 2025 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location 3_1_Generator_Y2025.xlsx#Operable:412
Sources EV-c170a24418642d0fc6fab76f Evidence SHA-256 2b27929d26cc1da9ad6a530da1cac6718cd8496098ee560c4d47cfffd96d08ba 행 SHA-256 5d459c3ec2e81d869a264ad8c1e39da5a37cfa82b8f6b94741b9a6e92a81468d Usage terms US government public domain
Observations for this power asset Source snapshots by date · USA · eia860m Belden / 1 Generator · Operations
Metric or condition Source value Basis, scope and stage
Detailed source fields Original source field Published value or condition Entity ID 14328 Entity Name Pacific Gas & Electric Co. Plant ID 219 Plant Name Belden Google Map Map Bing Map Map Plant State CA County Plumas Balancing Authority Code CISO Sector Electric Utility Generator ID 1 Nameplate Capacity (MW) 117.9 Net Summer Capacity (MW) 125 Net Winter Capacity (MW) 125 Technology Conventional Hydroelectric Energy Source Code WAT Prime Mover Code HY Operating Month 9 Operating Year 1969 Status (OP) Operating Latitude 40.007445 Longitude -121.2494 Original text (OP) Operating source_record_id Operating:414
Parent facility or plant record
No separate metric summary is available. Consult the detailed source fields.
Sources, reference dates and retrieval dates 1items eia860m ↗ Data Source 2026-08 · Retrieved 2026-10-05
Source: U.S. Energy Information Administration (EIA), 2025 final / August 2026 preliminary.
Source location Operating:414
Sources EV-b570d42ad715fe56b93a8b5c Evidence SHA-256 b4b70abb4c217e8e2658c3bde7608a3d530e86a81279ccc572ced82a200e9f1c 행 SHA-256 e1d7d2a0ec9bcb8de0f6c100ea0fec26cf6c86fe4946152104b27e5961ea218d Usage terms US government public domain
Observations for this power asset